You can create a secure aseptic processing workspace to prepare individual patient prescriptions while meeting the latest regulations, and protecting your patients and staff with the Bioquell Qube. This configurable isolator comes integrated with Bioquell’s Hydrogen Peroxide Vapour technology.
Ideal for:
Decontamination cycles in as little as 20 minutes for rapid so you can increase prescription throughput
Work in negative or positive pressure; Modular workspace to meet your needs from two to six gloves
Creates an ISO 5/EU Grade A cleanroom environment in your pharmacy while residing in a lower grade space
Meets or exceeds global regulatory compliance standards including USP 797 and USP 800
Built-in Bioquell Hydrogen Peroxide Vapour technology for reliable, repeatable decontamination results; easy-to-use touch-screen controls
Installed with no construction needed; requires a single outlet for power; no ductwork required; ready for use as soon as 12 weeks from order date
A drug’s impact can be negated by poor conditions while preparing and packaging. Even staff, such as nurses administering medicine, can be exposed to Hazardous Drugs (HDs) due to inferior equipment. Bioquell’s solutions allow you to ensure every exposed surface throughout your hospital pharmacy has received a validated decontamination, from the interior of a workstation through to the cleanroom and anteroom.
Outsourcing operations for compounding often means less control over quality and higher costs than performing these tasks internally, especially as your needs increase in quantity or turnaround time. Bioquell offers solutions to facilities opting to take charge of the compounding to maintain the drug’s integrity as well as keeping your patients and staff safe.
Whether you are working with Hazardous Drugs (HDs) or non-sterile compounding, you need to comply with the standards set forth such as USP 797 and USP 800. Bioquell offers unmatched solutions from compounding aseptic containment isolators (CACIs) to decontaminating your entire room to maintain acceptable particle counts.
Bioquell offers a modular and unique containment system with built-in hydrogen peroxide vapour decontamination that can be used for non-sterile and sterile compounding, and can be vented for Hazardous Drugs (HDs) preparation utilising negative pressure. Nearly any compounding operation can be performed comfortably and safely with the Bioquell Qube.
Fully integrated, pre-engineered options for total particulate and viable monitoring systems to help meet regulatory reporting requirements
Fully integrated, pre-engineered options for total particulate and viable monitoring systems to help meet regulatory reporting requirements
Options for optimising each chamber: full-size option for maximum storage of vials, delivery devices, reagents and other materials during decontamination cycles
Will this offer 21-CFR Part 11 compliance?
Yes, we are able to offer an optional data logger for this purpose.
What is the internal floor of the Bioquell Qube made from?
The floor of the Bioquell Qube is constructed from 316 stainless steel to ensure resistance to scratching on the working surface.
If my processes or needs evolve, is it possible to modify the Bioquell Qube accordingly?
The Bioquell Qube has been designed to allow for certain upgrades to be easily added after installation, such as adding a glove tester, particle counter, active air sampling device, racking or material transfer device (QMTD). These options are generally budget-friendly and can enhance your system’s capabilities. If you have specific future needs in mind, let’s discuss them today to ensure we design a solution that meets your current and future requirements effectively.
How can I bring tubing or cables into the Bioquell Qube?
We have an option for fitting a floor-mounted one-inch triclover port in each chamber. This allows you to bring in liquid lines or cables securely into the body of the Bioquell Qube.
What sets the Bioquell Qube apart from traditional stainless steel options?
The Bioquell Qube is constructed of tough and hard-wearing polypropylene, which is resistant to most materials the unit is ever likely to come into contact with. Because of its construction, the Bioquell Qube can be installed and validated within 16 weeks and, in most cases with minimal invasiveness to your operation or workflow.
Can you set alarms for the temperature inside the Bioquell Qube?
If I wish to change pressure from positive to negative, do I need to change the filters or take any additional action to ensure it is safe to use?
The Bioquell Qube can be switched between pressure regimes simply with the touch screen; no additional changes are needed.
Are there different leak tests programmed for the Bioquell Qube?
Yes, there are leak tests programmed for both positive and negative pressure.
To learn more about how Bioquell can fit your solution, please contact us.
Ecolab Ltd
52 Royce Cl,
Andover SP10 3TS, UK
+44 (0)1264 835 835
bioquell.enquiries@ecolab.com
To learn more about how Ecolab Life Sciences can fit your solution, please contact us.
Ecolab Ltd
52 Royce Cl,
Andover SP10 3TS, UK
+44 (0)1264 835 835
bioquell.enquiries@ecolab.com
5490